Standard and testing procedures in laboratory for coal log fabrication

No Thumbnail Available

Authors

Meeting name

Sponsors

Date

Journal Title

Format

Technical Report

Subject

Research Projects

Organizational Units

Journal Issue

Abstract

The quality of coal logs for transportation by CLP (Coal Log Pipeline) is determined mainly by the water resistance and wear resistance of the coal logs under conditions similar to those encountered in future commercial CLP. There are many factors that affect the quality of coal logs. They must be clearly specified and controlled in order to insure that good quality coal logs and consistent results are produced. The purpose of this document is to specify the procedures used in manufacturing and testing coal logs at the Capsule Pipeline Research Center (CPRC), University of Missouri--Columbia and Rolla campuses. All researchers on the two campuses must follow these procedures so that test data are reproducible on different days by different experimenters, and test results can be properly compared between researchers.

Table of Contents

Introduction -- Coal and coal mixture preparation -- Coal log compaction -- Curing of coal logs -- Water absorption test -- Wear resistance test -- Splitting tensile strength test.