    Thesis (15)
    SubjectMicroelectromechanical systems (2)Cells -- Classification (1)Cells -- Measurement -- Mathematical models (1)Micromachining (1)Miniature electronic equipment (1)... View MoreDate Issued2010 - 2018 (13)2007 - 2009 (2)Author/ContributorAlmasri, Mahmoud (15)Ghosh Dastider, Shibajyoti (2)Abdullah, Amjed (1)Al Yousuf, Rafal Qasim (1)Chang, Yushan (1)... View MoreAdvisor
    Almasri, Mahmoud (15)
    Thesis DepartmentElectrical engineering (MU) (12)Electrical and computer engineering (MU) (2)Engineering (MU) (1)Language (ISO)English (15)

    Browse

    All of MOspaceCommunities & CollectionsDate IssuedAuthor/ContributorTitleSubjectIdentifierThesis DepartmentThesis AdvisorThesis Semester

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular AuthorsStatistics by Referrer

    Search

    [+] Search or Limit by Field[-] Search or Limit by Field

    Keyword search by field

    Search or limit your keyword search by selected fields.

    Now showing items 1-15 of 15

    • Sort Options:
    • Relevance
    • Title (ascending order: A-Z)
    • Title (descending order: Z-A)
    • Date Issued (oldest first)
    • Date Issued (recent first)
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    MEMS Coulter counter for dynamic impedance measurement of time sensitive cells 

    Wu, Yifan (University of Missouri--Columbia, 2011)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] In this research, a MEMS Coulter counter is designed, modeled, fabricated and characterized, which can detect and monitor the dynamic cell impedance ...

    MEMS biosensor for detection of Escherichia coli O157:H7 in food products 

    Ghosh Dastider, Shibajyoti (University of Missouri--Columbia, 2011)
    Escherichia coli O157:H7, is one of the most common pathogens that has caused several outbreaks in recent years. In 2010-11 there were 5 outbreaks of E.coli and thousands were victim of it. Thus there is an immediate need ...

    Design and fabrication of one and two axis nickel electroplated micromirror array 

    Tondapu, Karthik (University of Missouri--Columbia, 2007)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] MEMS based micromirror devices are gaining importance at a steady pace in the applications related to optical communications and display technology. ...

    A MEMS based Coulter counter for cell sizing 

    Korampally, Madhuri (University of Missouri--Columbia, 2007)
    Detection and classification of cells forms an important aspect of medical research in diagnosing diseases and finding remedies at the cellular level. Miniaturized cell detecting devices are desirable not only for on site ...

    MEMS energy harvesters with a wide bandwidth for low frequency vibrations 

    Yuksek, Nuh Sadi (University of Missouri--Columbia, 2015)
    We have designed and built macro-scale wideband electrostatic and electromagnetic power harvesters for low frequency vibration. Initially, MEMS capacitive plates for power harvesting have been designed, modeled and fabricated, ...

    Noise optimization of amorphous SixGeyO1-x-y uncooled microbolometer 

    Jalal, Md Sayed Ebney (University of Missouri--Columbia, 2014)
    A detailed investigation of reduction of low-frequency noise voltage power spectral density (PSD) of silicon germanium oxide (SixGeyO1-x-y) uncooled infrared (IR) microbolometers has been performed. The experimental methods ...

    Signal generation for ultra-wideband short-range radar system 

    Zhou, Liang (University of Missouri--Columbia, 2012)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] In this thesis work, an ultra-wideband signal generator circuitry is presented for the Ultra-wideband Short-range Radar Human ID System. Investigation ...

    Micromachined PDMS elastic post arrays for studying vascular smooth muscle cells 

    Cheng, Qi (University of Missouri--Columbia, 2011)
    This thesis describes the design, modeling, fabrication and characterization of a micromachined array of high density 3-dimensional microposts (100 x 100) made of flexible material (silicone elastomers) for use to measure ...

    A mems variable capacitor with barium titanate (BaTiO3) dielectric layer for energy harvesting 

    Chen, Chen (University of Missouri--Columbia, 2015)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] In the research, a MEMS variable capacitor for electrostatic energy harvester was developed. The device uses the undesirable environmental mechanical ...

    Amorphous silicon germanium oxide (Si[sub]xGe[sub]yO[sub]1-x-y) thin films for uncooled infrared microbolometer 

    Hai, Muhammad Lutful (University of Missouri--Columbia, 2015)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] This dissertation presents a detailed characterization of amorphous Silicon Germanium Oxide (Si-Ge-O) thin films for uncooled infrared (IR) microbolometers. ...

    MEMS Impedance Biosensor for accurate and rapid detection of E.coli 0157:H7 

    Ghosh Dastider, Shibajyoti (University of Missouri--Columbia, 2016)
    Two Impedance biosensors based on interdigitated electrode (IDE) arrays were designed, fabricated and tested for detection of low concentration Escherichia coli O157:H7. The first biosensor consists of two set of gold IDE ...

    Controlled loading of cryoprotectants (CPAS) with cell volume constraints 

    Jasim, Ibrahem Hashim Mahmood (University of Missouri--ColumbiaUniversity of Missouri--Columbia, 2015)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] Oocyte cryopreservation techniques are considered very important aspects in biomedical research for oocyte and embryo cryopreservation to be used in ...

    MEMS parallel plate variable capacitor for energy harvesting 

    Chang, Yushan (University of Missouri--Columbia, 2015)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] In recent years, there is a dramatic increase in use of portable, wireless sensors and actuators which are widely powered by batteries. However, these ...

    MEMS impedance biosensor for accurate and rapid detection of E. coli O157:H7 in food products 

    Abdullah, Amjed (University of Missouri--Columbia, 2016)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] Escherichia coli O157:H7 is one of the public foodborne bacterial pathogens and results in severe illness such as diarrhea, urinary tract infections, ...

    Impedance based MEMS sensor for monitoring time sensitive oocyte cryopreservation 

    Al Yousuf, Rafal Qasim (University of Missouri--Columbia, 2018)
    [ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] In recent centuries, women in their 30s and 40s have represented an increasing portion of fertility patients who have had difficulties in fertilization. ...