Time-dependent response of flat plate structures under high sustained load
(University of Missouri--Columbia, 2022)
until failure or at least 20 days. Four-specimen groups consisting of 21 specimens constructed with scaled properties and average concrete age of 407 days were experimentally tested. Three of the specimens failed under sustained load at load levels...