[-] Show simple item record

dc.contributor.advisorMa, Hongbin, 1962-eng
dc.contributor.authorLaun, Fritzeng
dc.date.issued2013eng
dc.date.submitted2013 Falleng
dc.description"December 2013."eng
dc.description"A Thesis presented to the Faculty of the Graduate School University of Missouri--Columbia In Partial Fulfillment of the Requirements for the Degree Master of Science."eng
dc.descriptionThesis supervisor: Dr. Hongbin Ma.eng
dc.description.abstract[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] With ever increasing technological advances in electronics, modern computer components continue to produce higher power densities that present a challenge to thermal management. A radial flat-plate oscillating heat pipe (RFP-OHP) heat spreader is investigated to study the effect of central heating on the heat transport capability in an OHP. The investigated OHP has dimensions of 100 mm x 100 mm x 2.5 mm with central heating using a 30 mm x 30 mm heater. Experimental results show that when heat is added to the center section of one side of the radial flat-plate OHP, and when heat is removed from the whole surface of another side of the heat pipe, the startup power for the oscillating motion increases. In addition, the spacer effect on the heat transport capability including the startup is investigated experimentally. The spacer added between the cooling block and OHP could lower the startup power for oscillatory motion. When compared to a copper slab of the same dimensions in the same test configuration, the temperature difference for the OHP with and without the additional copper spacer was reduced by a maximum of 46 and 25%, respectively, at a power input of 525 W and a heat flux of 58 W/cm².eng
dc.description.bibrefIncludes bibliographical references (pages 19-21).eng
dc.format.extent1 online resource (vi, 21 pages) : illustrations (some color)eng
dc.identifier.oclc900092180eng
dc.identifier.urihttps://hdl.handle.net/10355/44717
dc.identifier.urihttps://doi.org/10.32469/10355/44717eng
dc.languageEnglisheng
dc.publisherUniversity of Missouri--Columbiaeng
dc.relation.ispartofcommunityUniversity of Missouri--Columbia. Graduate School. Theses and Dissertationseng
dc.rightsAccess is limited to the University of Missouri - Columbia.eng
dc.sourceSubmitted by the University of Missouri--Columbia Graduate Schooleng
dc.titleExperimental investigation of oscillating heat pipeseng
dc.typeThesiseng
thesis.degree.disciplineMechanical and aerospace engineering (MU)eng
thesis.degree.grantorUniversity of Missouri--Columbiaeng
thesis.degree.levelMasterseng
thesis.degree.nameM.S.eng


Files in this item

[PDF]
[PDF]
[PDF]

This item appears in the following Collection(s)

[-] Show simple item record