[-] Show simple item record

dc.contributor.authorMarri, Raj Kiran Reddy
dc.contributor.authorVerma, Shambhavi
dc.date.issued2016
dc.description.abstractThis paper deals with mechanical fault analysis of three phase induction motor using Motor Current Signature Analysis. This is a reliable technique that can be used to monitor the health of three phase induction motor. Three phase induction motor is used to find the Current Signature before and after the fault occurs. The FFT of Current signal is analyzed using Advanced Signal processor to find harmonics present before and after the fault occur. This data is used to detect the mechanical faults way before they cause harm to the motor and power system. Ball bearing fault is created practically to find the harmonics components in the current drawn. Most of the practical results match with the theoretical values obtained from the literature.eng
dc.identifier.issn1937-2647
dc.identifier.urihttps://hdl.handle.net/10355/49226
dc.publisherInterdisciplinary Doctoral Student Council at the University of Missouri-Kansas Cityeng
dc.relation.ispartofseriesJournal of Interdisciplinary Research;2016
dc.subjectthree phase induction motoreng
dc.subjectball bearing faulteng
dc.subjectFFTeng
dc.subjectharmonicseng
dc.subjectpower spectrumeng
dc.titleMCSA based mechanical fault analysis of three phase squirrel cage induction motoreng
dc.typeArticleeng


Files in this item

[PDF]

This item appears in the following Collection(s)

[-] Show simple item record