[-] Show simple item record

dc.contributor.advisorKovaleski, Scott D.eng
dc.contributor.authorBenwell, Andrew L., 1980-eng
dc.date.issued2007eng
dc.date.submitted2007 Falleng
dc.descriptionThe entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file.eng
dc.descriptionTitle from title screen of research.pdf file (viewed on March 18, 2008)eng
dc.descriptionIncludes bibliographical references.eng
dc.descriptionThesis (M.S.) University of Missouri-Columbia 2007.eng
dc.descriptionDissertations, Academic -- University of Missouri--Columbia -- Electrical engineering.eng
dc.description.abstractIncreasing performance of vacuum insulator barriers is a common goal in large pulsed power systems. Insulator performance is continually being improved while new methods are developed. Triple point shielding techniques have been shown to increase flashover voltage, but the role of cathode vs. anode shielding is still not fully understood. Magnetic flashover inhibition has been considered but has not been experimentally confirmed for 45 degree coaxial insulators. Open circuit flashover characteristics were obtained for a coaxial geometry to view the effects of triple point shielding for this geometry. The tests included applying various combinations of triple point shields on zero degree and +45 degree insulators. Shielding was tested at the cathode triple point outside of the dielectric and at the anode triple point inside the dielectric. Magnetic flashover inhibition was considered for 45 degree coaxial insulators. An experiment to test magnetic flashover inhibition was developed. The method could provide insight on how to configure a system to take advantage of magnetic flashover inhibition. The role of anode versus cathode triple point shielding was examined. Flashover voltage was observed to increase when either a cathode or anode triple point shield was applied; however adding a shield to both regions lowered the flashover threshold. Both triple point regions were found to be important and dependant on each other for some coaxial geometries.eng
dc.identifier.merlinb62764366eng
dc.identifier.oclc213470216eng
dc.identifier.urihttps://hdl.handle.net/10355/5018
dc.identifier.urihttps://doi.org/10.32469/10355/5018eng
dc.languageEnglisheng
dc.publisherUniversity of Missouri--Columbiaeng
dc.relation.ispartofcommunityUniversity of Missouri-Columbia. Graduate School. Theses and Dissertations. Theses. 2007 Theseseng
dc.subject.lcshElectric insulators and insulationeng
dc.subject.lcshPulse circuitseng
dc.subject.lcshPulsed power systemseng
dc.subject.lcshVacuum-tubeseng
dc.subject.lcshPolystyreneeng
dc.titleFlashover prevention on polystyrene high voltage insulators in a vacuumeng
dc.typeThesiseng
thesis.degree.disciplineElectrical and computer engineering (MU)eng
thesis.degree.grantorUniversity of Missouri--Columbiaeng
thesis.degree.levelMasterseng
thesis.degree.nameM.S.eng