[-] Show simple item record

dc.contributor.advisorGahl, John M. (John Michel)eng
dc.contributor.authorO'Donnell, Valentinaeng
dc.date.issued2016eng
dc.date.submitted2016 Springeng
dc.description.abstractA computational model of a proof-of-concept photoneutron source experiment was created and benchmarked. The neutron output from this system could be used for a number of therapies including Boron Neutron-Capture Therapy, BNCT. This benchmarked code was then modified to improve neutron output. The thermal neutron output of the benchmarked code was 1.33x10^5 neutrons/cm^2/sec. The goal was to increase the thermal neutron output to an output similar to a research reactor output: 10^8 or 10^9 neutrons/cm^2/sec. Modifications were made to different parts of the computationally modeled setup, including wall thicknesses, materials modeled, and volumes of liquids used in the experiment. Changes to the settings of the linear accelerator used were also made. These changes resulted in the desired increased neutron output from the system.eng
dc.identifier.urihttps://hdl.handle.net/10355/56127
dc.languageEnglisheng
dc.publisherUniversity of Missouri--Columbiaeng
dc.relation.ispartofcommunityUniversity of Missouri--Columbia. Graduate School. Theses and Dissertationseng
dc.rightsOpenAccess.eng
dc.rights.licenseThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License.
dc.titleExploration of an electron linear accelerator-driven photoneutron source for BNCTeng
dc.typeThesiseng
thesis.degree.disciplineNuclear engineering (MU)eng
thesis.degree.grantorUniversity of Missouri--Columbiaeng
thesis.degree.levelMasterseng
thesis.degree.nameM.S.eng


Files in this item

[PDF]
[PDF]
[PDF]

This item appears in the following Collection(s)

[-] Show simple item record