[-] Show simple item record

dc.contributor.advisorKim, Jung Hyupeng
dc.contributor.authorGuo, Wenbineng
dc.date.issued2016eng
dc.date.submitted2016 Summereng
dc.description.abstract[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT REQUEST OF AUTHOR.] The purpose of this study is to compare the pointing performance of mouse and eye-gaze input system to find the characteristics of the eye-gaze input system. By using a human-in-the-loop simulation, we could collect the participants' reaction time, accuracy and cognitive workload to evaluate the participants' ability to detect abnormal events during a visual searching task between different input systems. In this experiment, subjects were arbitrarily divided into two groups labeled mouse input system and eye-gaze input system. Fitts' law model, signal detection theory (SDT) and NASA task load index (NASA-TLX) were used to assess and compare participants' performance between different input systems. First, based on the Fitts' law model, we wanted to verify that whether there is a specific relationship between reaction time and index of difficulty (ID) for both mouse and eye-gaze input systems. The results presented that ID influenced the reaction time of mouse input, but the eye-gaze input system is less influenced by ID. For the eye-gaze input system, there was not linear pattern between reaction time and ID. Although the increase was small, reaction time had a certain degree of increase compared to different ID. On the other hand, the reaction time difference between mouse and eye-gaze became larger and larger as ID became higher. So there was a significant difference in reaction time between mouse and eye-gaze input systems. The eye-gaze input system had more distant click advantages than the mouse input system on the large screen and virtual reality environment. Second, for the mouse input system, normally if we reduced reaction time, the accuracy would decrease. However, the eye-gaze input system maintained the same accuracy but had a faster pointing time for operators. The mouse input system has more miss response, but eye-gaze input system has more false alarm response. So it is recommended to use either input system in different environments. Meanwhile, we should decrease the false alarm ratio to improve the accuracy of the eye-gaze input system. Third, people typically think the mouse input cognitive workload will be higher instead of eye-gaze. However, eye-gaze input maintained the same cognitive workload compared with mouse input system. All the findings can be utilized to provide deeper insight into user behavior analysis regarding different input systems. The results showed the potential of eye-gaze input as a valuable tool for advanced human-computer interfaces if participants are well-trained to use eye-gaze input system in which the eye tracking device accuracy is good enough.eng
dc.description.bibrefIncludes bibliographical references.eng
dc.format.extent1 online resource (viii, 66 pages) : illustrationseng
dc.identifier.urihttps://hdl.handle.net/10355/61115
dc.languageEnglisheng
dc.publisherUniversity of Missouri--Columbiaeng
dc.relation.ispartofcommunityUniversity of Missouri--Columbia. Graduate School. Theses and Dissertationseng
dc.rightsAccess is limited to the campuses of the University of Missouri.eng
dc.titleComparing pointing performance of mouse and eye-gaze input systemeng
dc.typeThesiseng
thesis.degree.disciplineIndustrial and manufacturing systems engineering (MU)eng
thesis.degree.grantorUniversity of Missouri--Columbiaeng
thesis.degree.levelMasterseng
thesis.degree.nameM.S.eng


Files in this item

[PDF]
[PDF]
[PDF]

This item appears in the following Collection(s)

[-] Show simple item record