Shared more. Cited more. Safe forever.
    • advanced search
    • submit works
    • about
    • help
    • contact us
    • login
    View Item 
    •   MOspace Home
    • University of Missouri-Columbia
    • Faculty Research, Scholarship, and Creative Works (MU)
    • Faculty Research, Scholarship, and Creative Works (MU)
    • View Item
    •   MOspace Home
    • University of Missouri-Columbia
    • Faculty Research, Scholarship, and Creative Works (MU)
    • Faculty Research, Scholarship, and Creative Works (MU)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.
    advanced searchsubmit worksabouthelpcontact us

    Browse

    All of MOspaceCommunities & CollectionsDate IssuedAuthor/ContributorTitleIdentifierThesis DepartmentThesis AdvisorThesis SemesterThis CollectionDate IssuedAuthor/ContributorTitleIdentifierThesis DepartmentThesis AdvisorThesis Semester

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular AuthorsStatistics by Referrer

    Influence of pH, ionic strength and natural organic matter concentration on a MIP-Fluorescent sensor for the quantification of DNT in water

    Dai, J.
    Fidalgo, de Cortalezzi M.
    View/Open
    [PDF] Fidalgo.pdf (175.4Kb)
    Date
    2019
    Format
    Article
    Metadata
    [+] Show full item record
    Abstract
    The effect of sample water chemistry on a carbon dot labeled molecularly imprinted polymer (AC-MIP) sensor for the detection of 2,4-dinitrotoluene (DNT) was investigated. Hydrogel MIP films were fabricated and tested in DNT solutions in various matrices, representative of natural water conditions, to assess applicability of the sensors to real water samples. The effect of pH, natural organic matter (NOM), ionic strength and cation type on the swelling of the hydrogel and fluorescence quenching was investigated. An increase in ionic strength from 1 mM to 100 mM produced a quenching amount of MIPs decreased of about 19 percent and 30 percent with NaCl and CaCl2 respectively. In the range of pH tested, from 4 to 9, quenching was higher at basic environment for both MIPs and non-imprinted polymers (NIPs) due to increased hydrogel swelling. NOM contributed to the background quenching, but the effect could be addressed by an adjusted calibration equation. In both lake and tap water, DNT concentrations read by the sensors were close to the values measured by HPLC, within 72 percent–105 percent of true values. The AC-MIP films fabricated in this work are promising materials for the detection of water contamination in the field and the quantitative analysis of DNT concentration.
    URI
    https://dx.doi.org/10.1016/j.heliyon.2019.e01922
    https://hdl.handle.net/10355/74570
    Rights
    OpenAccess.
    This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.
    https://creativecommons.org/licenses/by-nc-nd/4.0
    Collections
    • Civil and Environmental Engineering presentations (MU)
    • Faculty Research, Scholarship, and Creative Works (MU)

    Send Feedback
    hosted by University of Missouri Library Systems
     

     


    Send Feedback
    hosted by University of Missouri Library Systems